A guardrail top rail must withstand a force of at least how many pounds applied outward or downward at any point along its top edge?
- 100 pounds
- 150 pounds
- 200 pounds
- 500 pounds
Show the answer
C. 200 pounds
The top rail must resist at least 200 pounds in an outward or downward direction. The 150-pound figure is the requirement for midrails and other intermediate members.
Reference: 29 CFR 1926.502(b)(3)
A personal fall arrest system must be rigged so that the worker can free fall no more than what distance and cannot contact a lower level?
- 2 feet
- 4 feet
- 6 feet
- 10 feet
Show the answer
C. 6 feet
Free fall is limited to 6 feet, and the worker must not strike a lower level. Two feet is the limit for a positioning device system, not a fall arrest system.
Reference: 29 CFR 1926.502(d)(16)(iii)
Unless it is engineered as part of a complete system, an anchorage for a personal fall arrest system must support at least how much per worker attached?
- 1,800 pounds
- 3,000 pounds
- 3,600 pounds
- 5,000 pounds
Show the answer
D. 5,000 pounds
An anchorage must hold 5,000 pounds for each worker attached. The 1,800-pound figure is the maximum arresting force on the body, not the anchor strength.